Skip to Main Content (Press Enter)

Logo UNINSUBRIA
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNINSUBRIA

|

UNI-FIND

uninsubria.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

A Multicenter Global Registry of Paclitaxel Drug-Coated Balloon in Dysfunctional Arteriovenous Fistulae and Grafts: 6-Month Results

Articolo
Data di Pubblicazione:
2021
Abstract:
Purpose: To assess the safety and clinical benefit of the Lutonix drug-coated balloon (DCB) catheter for the treatment of dysfunctional arteriovenous fistulae (AVF) and grafts (AVG) in a heterogenous real-world population. Materials and Methods: This multicenter, prospective study enrolled 320 subjects from 12 countries in 25 sites across Europe and Asia. A total of 392 lesions were treated with the Lutonix 035 DCB catheter. Lesions were de novo and restenotic, located in every part of the circuit from the cannulation zone to central venous outflow. In-stent restenotic lesions also were treated. The primary safety endpoint was freedom from serious adverse events involving the access circuit through 30 days. The primary effectiveness endpoint was target lesion primary patency (TLPP) through 6 months. Secondary endpoints included access circuit primary patency (ACPP) at 6 months and the investigation of factors that would independently influence the primary endpoints. Results: The primary safety endpoint was 95.5%, while TLPP was 73.9% at 6 months, per Kaplan-Meier survival analysis. ACPP was 71% at 6 months. TLPP for stenosis of AVFs was 78.1%. Subgroup analysis showed significantly improved TLPP when DCB was dilated for ≥120 seconds (P = .007). TLPP was significantly better when predilation occurred compared with cases where only DCB angioplasty was performed (77% vs 48.6%, P = .0005). Conclusions: The Lutonix AV Global Registry confirms that the Lutonix DCB is a safe and effective treatment option in real-world patients with dysfunctional AVF or AVG. Procedural details had a significant role in TLPP. No significant difference in TLPP was observed among different treatment areas.
Tipologia CRIS:
Articolo su Rivista
Keywords:
Aged; Aged, 80 and over; Angioplasty, Balloon; Arteriovenous Shunt, Surgical; Asia; Blood Vessel Prosthesis Implantation; Cardiovascular Agents; Europe; Female; Graft Occlusion, Vascular; Humans; Male; Middle Aged; Paclitaxel; Prospective Studies; Recurrence; Registries; Risk Factors; Time Factors; Treatment Outcome; Vascular Patency; Coated Materials, Biocompatible; Renal Dialysis; Vascular Access Devices
Elenco autori:
Karnabatidis, D.; Kitrou, P. M.; Ponce, P.; Chong, T. T.; Pietura, R.; Pegis, J. -D.; Ko, P. -J.; Lin, C. H.; Tozzi, M.; Lucas, C.; Chien-Hwa Chang, J.; Deutschmann, H.; Jaffer, O.; Ferrario, A.; Saracino, G.; Steiner, K.; Pei Ho, J.; van den Berg, J.; Boura, B.; Mishunin, D.; Ahmad, F.; Teichgraeber, U.; Cioni, R.; Huang, H. -L.; Arabi, M.; Savio, D.
Autori di Ateneo:
Centro di ricerche in Radiologia Interventistica
Centro di ricerche per lo studio e l'applicazione di nuove tecnologie in chirurgia vascolare
TOZZI MATTEO
Link alla scheda completa:
https://irinsubria.uninsubria.it/handle/11383/2127654
Pubblicato in:
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY
Journal
  • Accessibilità
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.7.0.0