Data di Pubblicazione:
2009
Abstract:
The SiPMs are excellent candidates for the replacement of PMTs in many experimental situations. In this article we describe the performances of different types of SiPMs from Hamamatsu and FBK-IRST before and after irradiation with photons and neutrons in terms of signal to noise ratio, time resolution and efficiency. The SiPMs are connected to a scintillation tracker/calorimeter, composed of eight layers (4x and 4y) of 10 scintillating bars each and have been tested at the CERN PS T9 beamline. The tracker/calorimeter is a small-size prototype of a bigger detector called EMR (Electron Muon Ranger), a particle identification system developed for the MICE experiment.
Tipologia CRIS:
Articolo su Rivista
Keywords:
Silicon PhotoMultiplier; MICE; scintillator; CERN
Elenco autori:
Berra, ALESSANDRO JOSE' FRANCESCO; Bolognini, D; Bonvicini, V; Cauz, D; Driutti, A; Giannini, G; Hasan, S; Iugovaz, D; Lietti, Daniela; Mascagna, V; Mattera, A; Pauletta, G; Penzo, A; Prest, Michela; Rashevskaya, I; Reia, S; Vallazza, E.
Link alla scheda completa: