Outcomes of Transcatheter Aortic Valve Implantation Comparing Medtronic's Evolut PRO and Evolut R: A Systematic Review and Meta-Analysis of Observational Studies

Articolo
Data di Pubblicazione:
2023
Abstract:
Background: Transcatheter aortic valve implantation (TAVI) has become a broadly acceptable alternative to AV surgery in patients with aortic stenosis (AS). New valve designs are becoming available to address the shortcomings of their predecessors and improve clinical outcomes. Methods: A systematic review and meta-analysis was carried out to compare Medtronic's Evolut PRO, a new valve, with the previous Evolut R design. Procedural, functional and clinical endpoints according to the VARC-2 criteria were assessed. Results: Eleven observational studies involving N = 12,363 patients were included. Evolut PRO patients differed regarding age (p < 0.001), sex (p < 0.001) and STS-PROM estimated risk. There was no difference between the two devices in terms of TAVI-related early complications and clinical endpoints. A 35% reduction of the risk of moderate-to-severe paravalvular leak (PVL) favoring the Evolut PRO was observed (RR 0.66, 95%CI, [0.52, 0.86] p = 0.002; I2 = 0%). Similarly, Evolut PRO-treated patients demonstrated a reduction of over 35% in the risk of serious bleeding as compared with the Evolut R (RR 0.63, 95%CI, [0.41, 0.96]; p = 0.03; I2 = 39%), without differences in major vascular complications. Conclusions: The evidence shows good short-term outcomes of both the Evolut PRO and Evolut R prostheses, with no differences in clinical and procedural endpoints. The Evolut PRO was associated with a lower rate of moderate-to-severe PVL and major bleeding.
Tipologia CRIS:
Articolo su Rivista
Keywords:
Evolut PRO; Evolut R; TAVI; aortic stenosis; heart failure; meta-analysis; paravalvular leak; permanent pacemaker; transcatheter intervention
Elenco autori:
Gozdek, Mirosław; Kuźma, Łukasz; Dąbrowski, Emil Julian; Janiak, Michał; Pietrzak, Martyna; Skonieczna, Karolina; Woźnica, Mikołaj; Wydeheft, Lidia; Makhoul, Maged; Matteucci, Matteo; Litwinowicz, Radosław; Kowalówka, Adam; Wańha, Wojciech; Pasierski, Michał; Ronco, Daniele; Massimi, Giulio; Jiritano, Federica; Fina, Dario; Martucci, Gennaro; Raffa, Giuseppe Maria; Suwalski, Piotr; Lorusso, Roberto; Meani, Paolo; Kowalewski, Mariusz
Autori di Ateneo:
MATTEUCCI MATTEO
Link alla scheda completa:
https://irinsubria.uninsubria.it/handle/11383/2173451
Pubblicato in:
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH