A method for the dynamic range extension of a pixelated Silicon detector beam profilometer based on the incomplete reset mechanism

Contributo in Atti di convegno
Data di Pubblicazione:
2017
Abstract:
The SUCIMA collaboration, within a project supported by the European Commission in the Fifth Framework Program, developed a sensor for non-disruptive real-time beam profilometry for hadron therapy centres. The sensor, named MIMOTERA, has been used at different European facilities, imaging beams by direct impact on the sensor and by the detection of secondary electrons emitted by thin targets. In 2015, the detector has been thinned to 50 μm, integrated in a high vacuum and cryogenic temperature compliant assembly and successfully commissioned as antiproton beam monitor for the AEIS experiment at CERN. The detector contributed to the optimisation of the experiment functionality providing the shape and position of the beam on a spill-by-spill basis. However, it failed in measuring the fluctuations of the beam intensity because the deposited energy exceeded the full well capacity and saturated the output signal. In order to recover this information, a method was developed based on the persistence of the signal in a series of frames that follows the one corresponding to the beam impact, due to the incomplete sensor reset. A laboratory test that makes use of a laser with tuneable intensity was designed and the method was qualified. This paper reports the description of the procedure and the main outcomes.
Tipologia CRIS:
Relazione (in Rivista)
Keywords:
beam-intensity monitors; Beam-line instrumentation (beam position and profile monitors; bunch length monitors); Solid state detectors; Instrumentation; Mathematical Physics
Elenco autori:
Caccia, MASSIMO LUGI MARIA; Santoro, Romualdo; Antonello, Massimiliano
Autori di Ateneo:
CACCIA MASSIMO LUIGI MARIA
SANTORO ROMUALDO
Link alla scheda completa:
https://irinsubria.uninsubria.it/handle/11383/2061920
Pubblicato in:
JOURNAL OF INSTRUMENTATION
Journal
  • Dati Generali

Dati Generali

URL

http://iopscience.iop.org/article/10.1088/1748-0221/12/03/C03033/pdf
  • Accessibilità
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0