EMG AND FORCES DURING MANOEUVRING OF
CEILING-BASED AND FLOOR-BASED PATIENT TRANSFER DEVICES.
A laboratory and on-the-field study was conducted to compare
Floor-Based (FB) and Ceiling-Based (CB) patients transfer
devices. Pushing and pulling forces were measured by means
of computer assisted dynamometer. EMG signals were
measured. Standardized patient transfers were setup in the room
(bed-chair-door-return). FB devices showed pushing and pulling
forces higher than CB ones. CB paths were the smoothest and
EMG data related to upper arms and trunk muscles showed
stable lower loads for CB. The study suggests that CB patient
transfer devices reduced the load. CBs seem the best tools for
patient handling