Skip to Main Content (Press Enter)

Logo UNINSUBRIA
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Projects
  • Expertise & Skills

UNI-FIND
Logo UNINSUBRIA

|

UNI-FIND

uninsubria.it
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Projects
  • Expertise & Skills
  1. Outputs

Decolorization and biodegradability of a real pharmaceutical wastewater treated by H2O2-assisted photoelectrocatalysis on TiO2 meshes

Academic Article
Publication Date:
2020
abstract:
In recent years, photoelectrocatalysis (PEC) for the treatment of industrial wastewaters (IWWs) has been repeatedly proposed. However, despite the number of tests reported in literature, only a few of them were conducted on real IWWs. In this study, real pharmaceutical IWWs showing an intense recalcitrant color were treated by PEC and H2O2-assisted PEC (UV/TiO2/Bias and UV/H2O2/TiO2/Bias, respectively) on TiO2 meshes having sub-micrometric features obtained by Plasma Electrolytic Oxidation. Photolysis (UV), chemical oxidation (H2O2) and H2O2-assisted photolysis (UV/H2O2) were tested in the same reactor for comparison. The configuration UV/H2O2/TiO2/bias showed the best results in term of decolorization efficiency and rate, where decolorization was 55 % (single-step H2O2 dosing) and 44 % (three-step H2O2 dosing), after 2 h of contact time. In the same contact time, UV and UV/TiO2/Bias processes did not give decolorization. A more effective COD removal was measured for the PEC processes, UV/H2O2/TiO2/Bias (-24 %) and UV/TiO2/Bias (-20 %), while COD removal by UV was almost 0 %. Correspondingly, the SOUR values showed that PEC combined with a single-step H2O2 dosage was the most effective configuration, leading to the highest biodegradability of the treated IWW with respect to the other processes. The energy consumption analysis demonstrated that PEC+H2O2 (single-step dosage) optimized energy costs.
Iris type:
Articolo su Rivista
Keywords:
AOPs; Electrochemical processes; Pharmaceutical wastewater; Photoelectrocatalysis; Titanium dioxide
List of contributors:
Collivignarelli, M. C.; Abba, A.; CARNEVALE MIINO, Marco; Arab, H.; Bestetti, M.; Franz, S.
Authors of the University:
CARNEVALE MIINO MARCO
Handle:
https://irinsubria.uninsubria.it/handle/11383/2162252
Published in:
JOURNAL OF HAZARDOUS MATERIALS
Journal
  • Overview

Overview

URL

https://doi.org/10.1016/j.jhazmat.2019.121668
  • Accessibility
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.4.0.0