Skip to Main Content (Press Enter)

Logo UNINSUBRIA
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Projects
  • Expertise & Skills

UNI-FIND
Logo UNINSUBRIA

|

UNI-FIND

uninsubria.it
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Projects
  • Expertise & Skills
  1. Outputs

Virtual non-contrast spectral CT in renal masses: is it time to discard conventional unenhanced phase?

Academic Article
Publication Date:
2023
abstract:
Dual-layer Dual-Energy CT (dl-DECT) allows one to create virtual non-contrast (VNC) reconstructions from contrast-enhanced CT scans, with a consequent decrease of the radiation dose. This study aims to assess the reliability of VNC for the diagnostic evaluation of renal masses in comparison with true non-contrast (TNC) images. The study cohort included 100 renal masses in 40 patients who underwent dl-DECT between June and December 2021. Attenuation values and standard deviations were assessed through the drawing of regions of interest on TNC and VNC images reconstructed from corticomedullary and nephrographic phases. A Wilcoxon signed-rank test was performed in order to assess equivalence of data and Spearman’s Rho correlation coefficient to evaluate correlations between each parameter. The diagnostic accuracy of VNC was estimated through the performance of receiver operating characteristic (ROC) curve analysis. Differences between attenuation values were, respectively, 74%, 18%, 5% and 3% (TNC-VNCcort), and 74%, 15%, 9% and 2% (TNC-VNCneph). The Wilcoxon signed-rank test demonstrated the equivalence of attenuation values between the TNC and VNC images. The diagnostic performance of VNC images in the depiction of kidney simple cysts remains high compared to TNC (VNCcort-AUC: 0.896; VNCneph-AUC: 0.901, TNC-AUC: 0.903). In conclusion, quantitative analysis of attenuation values showed a strong agreement between VNC and TNC images in the evaluation of renal masses.
Iris type:
Articolo su Rivista
Keywords:
computed tomography; dual energy; findings incidental kidney; virtual non-contrast image
List of contributors:
Bucolo, G. M.; Ascenti, V.; Barbera, S.; Fontana, F.; Arico, F. M.; Piacentino, F.; Coppola, A.; Cicero, G.; Marino, M. A.; Booz, C.; Vogl, T. J.; D'Angelo, T.; Venturini, M.; Ascenti, G.
Authors of the University:
COPPOLA ANDREA
FONTANA FEDERICO
PIACENTINO FILIPPO
VENTURINI MASSIMO
Handle:
https://irinsubria.uninsubria.it/handle/11383/2162092
Full Text:
https://irinsubria.uninsubria.it//retrieve/handle/11383/2162092/237458/Virtual-NonContrast-Spectral-CT-in-Renal-Masses-Is-It-Time-to-Discard-Conventional-Unenhanced-PhaseJournal-of-Clinical-Medicine.pdf
Published in:
JOURNAL OF CLINICAL MEDICINE
Journal
  • Accessibility
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.9.3.0