Elective Embolization of Splenic Artery Aneurysms with an Ethylene Vinyl Alcohol Copolymer Agent (Squid) and Detachable Coils

Articolo
Data di Pubblicazione:
2020
Abstract:
Purpose: To report the safety and efficacy of the embolization of splenic artery aneurysms (SAAs) with coils plus ethylene vinyl alcohol copolymer (EVOH) agent. Materials and Methods: A single-center retrospective study was conducted from 2016 to 2019 to collect SAAs. Twelve asymptomatic patients (mean age, 59 years) with 15 SAAs (mean size, 23.6 mm; size range, 15–40 mm) were treated with embolization. Embolization was performed with EVOH (Squid 8/34) and fibered detachable coils. Transfemoral embolization was performed with a microcatheter to achieve a splenic artery occlusion embolizing the SAA and its efferent and afferent branches. Follow-up was based on color Doppler ultrasound at 24 hours and on computed tomography (CT) angiography at 1 (n = 12) and 6 months (n = 12) after embolization. Mean number of coils and Squid vials used for each patient, major/minor complications, technical success, 30-day clinical success, cases of revascularization/reintervention, and mortality were assessed. Technical success was defined as complete exclusion of the aneurysmal segment and cessation of blood flow into the sac. Clinical success at 1 month was based on the absence of clinical symptoms and the exclusion of aneurysm revascularization on CT angiography. Results: The mean number of coils and Squid vials was 5.75 (standard deviation [SD], 1.58; range, 3–9) and 1.41 (SD, 0.49; range, 1–2), respectively. Both technical and 30-day clinical success were 100%, with no cases of aneurysm revascularization (CT angiography performed in all patients at 1 month and 6 months and in 3 patients at 24 months). No major complications or fatal events were recorded. In terms of minor complications, 2 cases of mild pancreatitis (transient amylases increase) and 1 case of focal splenic ischemia without clinical sequelae were recorded. Conclusions: Embolization in SAAs using coils plus EVOH was safe and effective without SAA revascularization
Tipologia CRIS:
Articolo su Rivista
Elenco autori:
Venturini, M.; Marra, P.; Augello, L.; Colarieti, A.; Guazzarotti, G.; Palumbo, D.; Lanza, C.; Melissano, G.; Chiesa, R.; De Cobelli, F.
Autori di Ateneo:
Centro di ricerche in Radiologia Interventistica
VENTURINI MASSIMO
Link alla scheda completa:
https://irinsubria.uninsubria.it/handle/11383/2094704
Pubblicato in:
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY