Skip to Main Content (Press Enter)

Logo UNINSUBRIA
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNINSUBRIA

|

UNI-FIND

uninsubria.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Transcatheter Aortic Valve Implantation (TAVI) Planning with Dual-Layer Spectral CT Using Virtual Monoenergetic Image (VMI) Reconstructions and 20 mL of Contrast Media

Articolo
Data di Pubblicazione:
2024
Abstract:
Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to surgical implantation and its implementation is progressively increasing worldwide. We routinely perform pre-procedural aortic angiography CT to assess aortic dimensions and vascular anatomy. This study aims to evaluate the image quality of CTA for TAVI planning using dual-layer spectral CT, with virtual monoenergetic image reconstructions at 40 keV. Thirty-one patients underwent a CTA protocol with the injection of 20 mL of contrast media. Image quality was assessed by measuring the mean density in Hounsfield Units (HU), the signal-to-noise ratio, and the contrast-to-noise ratio in VMI reconstructions. Additionally, a blinded subjective analysis was conducted by two observers. The results showed significant enhancement at all sampled vascular levels with a gradual decrease in HU from proximal to distal regions. Favourable subjective ratings were given for all parameters, with greater variability in the evaluation of iliac axes. A significant negative correlation (p < 0.05) was observed between BMI and CA at all vascular levels, indicating reduced contrast enhancement with increasing BMI. Spectral CT, along with reducing iodine load, allows for obtaining high-quality images without a significant increase in noise. The reduction in iodine load can have positive implications in clinical practice, improving patient safety and resource efficiency.
Tipologia CRIS:
Articolo su Rivista
Keywords:
TAVI planning; dual-layer spectral CT; image quality; iodine load reduction; patient safety; transcatheter aortic valve implantation; vascular anatomy assessment; virtual monoenergetic images
Elenco autori:
Fontana, Federico; Piacentino, Filippo; Gnesutta, Aroa; Macchi, Edoardo; Coppola, Andrea; Saccomanno, Angiola; Gatta, Tonia; Recaldini, Chiara; Minenna, Manuela; Tamborini, Claudio; Dossi, Filippo; Ascenti, Velio; Barbera, Simone; Cicero, Giuseppe; Carcano, Giulio; Ascenti, Giorgio; Castiglioni, Battistina; Venturini, Massimo
Autori di Ateneo:
CARCANO GIULIO
COPPOLA ANDREA
Chirurgia
FONTANA FEDERICO
PIACENTINO FILIPPO
VENTURINI MASSIMO
Link alla scheda completa:
https://irinsubria.uninsubria.it/handle/11383/2166853
Link al Full Text:
https://irinsubria.uninsubria.it//retrieve/handle/11383/2166853/246564/jcm-13-00524.pdf
Pubblicato in:
JOURNAL OF CLINICAL MEDICINE
Journal
  • Accessibilità
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0