  1. Pubblicazioni

Evolution of practice patterns and learning curve of aortic repair using the E-nside off-the-shelf inner branch thoracoabdominal endograft

Articolo
Data di Pubblicazione:
2025
Abstract:
Objective: To report the impact of the learning curve on the outcomes of branched endovascular aortic repair using an off-the-shelf preloaded inner branch device (E-nside). Methods: Data from a physician-initiated national multicenter registry, including patients treated with E-nside endograft (INBREED [ItaliaN Branch Registry of E-nside EnDograft]) were collected prospectively (2020-2024). End points were early (30-day) technical success, mortality, major adverse events (MAEs), and 2-year freedom from endograft instability and target vessel instability. Patients were divided into early and late cohorts based on the median date of the procedure in each center. Results: There were 215 patients treated with the E-nside, 108 (393 target vessels) in the early and 107 (395 target vessels) in the late cohort. Most patients had a degenerative aneurysm (early, 82%; late, 75%; P = .326) or a chronic dissection (early, 6%; late, 15%; P = .025). Aneurysm extent was thoracoabdominal in 53% of patients and complex abdominal in 47%; and 23% were ruptured or symptomatic and 26% had an aneurysm size of more than 70 mm, without differences between groups. A narrow paravisceral aortic lumen of less than 25 mm was more frequent in the late cohort (late, 30%; early, 18%; P = .037). From the early to the late groups, there was an increase in the use of a total transfemoral approach (late, 29% vs early, 18%; P = .042), balloon-expandable bridging stents (late, 82% vs early, 76%; P = .032), and reinforcement bridging stents (late, 26%; early, 11%; P < .001). Operating time (late, 267 ± 131 minutes; early, 244 ± 130 minutes; P = .230), iodinated contrast volume (late, 181 ± 81 mL; early, 210 ± 141 mL; P = 108; P = .302), and dose area product (late, 272 ± 110 Gycm2 early, 291 ± 118 Gycm2; P = .277) were similar in the two groups. Intraprocedural complications decreased in the later stage of the learning curve (late, 11%; early, 23%; P = .030), whereas overall 30-day mortality (late, 8%; early, 6%; P = .346), technical success (late, 99%; early, 98%; P = .286), and MAEs (late, 27%; early, 29%; P = .879) remained substantially stable. There were no differences in 2-year freedom from endograft instability (late, 100 ± 0%; early, 96 ± 5%; P = 1.00), freedom from target vessel instability (late, 98 ± 3%; early, 94 ± 2%; P = .090), and target vessel primary patency (late, 97 ± 2%; early, 97 ± 2%; P = .321). Conclusions: The increased experience with the E-nside endograft was associated with a more frequent use of a total transfemoral approach and use of balloon-expandable and reinforced bridging stents. From the early to the late stages, there was a significant decrease in intraoperative complications, although most centers were learning independent and achieved a consistent mortality, MAE, procedural metrics, and mid-term results from the start.
Tipologia CRIS:
Articolo su Rivista
Keywords:
Aortic aneurysm; Aortic dissection; Branched endovascular aortic repair; Learning curve; Off-the-shelf; physician; Practice patterns
Elenco autori:
Squizzato, F.; Piazza, M.; Piffaretti, G.; Gatta, E.; Tshomba, Y.; Orrico, M.; Ronchey, S.; Bozzani, A.; Pratesi, G.; Gaggiano, A.; Simonte, G.; Mansour, W.; Antonello, M.; Piazza, M.; Squizzato, F.; Spezia, M.; Grego, F.; Pratesi, G.; Spinella, G.; Esposito, D.; Bastianon, M.; Tshomba, Y.; Donati, T.; Sica, S.; Tinelli, G.; Ferri, M.; Quaglino, S.; Gaggiano, A.; Vento, V.; Carbonari, L.; Gatta, E.; Lenti, M.; Simonte, G.; Isernia, G.; Parlani, G.; Piffaretti, G.; Frigatti, P.; Scrivere, P.; Furlan, F.; Veraldi, G. F.; Mezzetto, L.; Gennai, S.; Leone, N.; Silingardi, R.; Iacono, G.; Turricchia, G. U.; Angiletta, D.; Maione, M.; Apostolou, D.; Pulli, R.; Filippi, F.; De Angelis, F.; Arici, V.; Bozzani, A.; Luigi Molinari, A. C.; Rossi, G.; Brancadoro, E. C.; Ferraris, M.; Dall'Antonia, A.; Derone, G.; Porcellato, L.; Tolva, V. S.; Compagnoni, N. M.; Segramora, V. M.; Deleo, G.; Bracale, U.; Turchino, D.; Guzzardi, G.; Ferrer, C.; Giudice, R.; Sbarigia, E.; Cuozzo, S.; Gattuso, R.; Mansour, W.; Di Marzo, L.; Grimaldi, S.; Corona, M.; Chisci, E.; Michelagnoli, S.; De Donato, G.; Palasciano, G.; Pasqui, E.; Candeloro, L.; Ricci, C.; Neri, E.; Mangialardi, N.; Orrico, M.; Fazzini, S.; Martelli, E.; Discalzi, A.; Rossato, D.; Vio, E.; Galeazzi, E.; Bonardelli, S.; Bertoglio, L.; Melloni, A.; Grandi, A.; Volpe, P.; Massara, M.; Milite, D.; Xodo, A.; Ronchey, S.
Autori di Ateneo:
PIFFARETTI GABRIELE
PIFFARETTI GABRIELE
Link alla scheda completa:
https://irinsubria.uninsubria.it/handle/11383/2216084
Link al Full Text:
https://irinsubria.uninsubria.it//retrieve/handle/11383/2216084/516074/INBREED%20practice%20pattern.pdf
Pubblicato in:
JOURNAL OF VASCULAR SURGERY
Journal