Skip to Main Content (Press Enter)

Logo UNINSUBRIA
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNINSUBRIA

|

UNI-FIND

uninsubria.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Multicentric study of endobronchial ultrasound-transbronchial needle aspiration for lung cancer staging in Italy

Articolo
Data di Pubblicazione:
2017
Abstract:
Background: Multi-institutional studies of endobronchial-ultrasound transbronchial needle aspiration (EBUS-TBNA) for mediastinal staging in lung cancer are scarce. It is unclear if the high diagnostic performance of EBUS-TBNA reported by experts' guidelines can be generally achieved. Methods: This is a retrospective study performed in five tertiary referral centers of thoracic surgery in Italy, to assess the EBUS-TBNA diagnostic performance in patients with non-small cell lung cancer (NSCLC). Patient inclusion criteria were: both genders; > 18 years old; with suspect/confirmed NSCLC; undergoing EBUSTBNA for mediastinal node enlargement at computed tomography (size > 1 cm, â ¤3 cm) and/or pathological uptake at positron emission tomography. Altogether we included 485 patients [male, 366; female, 119; median age, 68 years (IQR, 61-74 years)] undergoing mediastinal staging between January 2011 and July 2016. All EBUS-TBNAs were performed by experienced bronchoscopists, without pre-defined quality standards. Depending on usual practice in each center, EBUS-TBNA was done under conscious sedation, with 21- or 22-Gauge (G) needle, and specimen preparation was cell-block, or cytology slides, or core-tissue. Sampling was classified inadequate in absence of lymphocytes, or when sample was insufficient. We analyzed the EBUSTBNA procedural steps likely to influence the rate of adequate samplings (diagnostic yield). Results: EBUS-TBNA sensitivity, negative predictive value (NPV) and accuracy respectively were 90%, 78% and 93% in the whole cohort. At multivariate analysis, use of 21-G needle was associated with better diagnostic yield (P < 0.001). Center and specimen processing technique were not independent factors affecting EBUS-TBNA diagnostic yield. Conclusions: In this multicentric study, EBUS-TBNA was a highly sensitive and accurate method for NSCLC mediastinal node staging. Results indicate better performance of EBUS-TBNA with 21-G needle, and suggest that specimen processing technique could be chosen according to the local practice preference.
Tipologia CRIS:
Articolo su Rivista
Keywords:
Accuracy; Diagnostic yield; Endobronchial ultrasound-transbronchial needle aspiration (EBUS-TBNA); Lung cancer staging; Pulmonary and Respiratory Medicine
Elenco autori:
Rotolo, Nicola; Imperatori, ANDREA SELENITO; Nosotti, Mario; Santambrogio, Luigi; Palleschi, Alessandro; Dominioni, Lorenzo; Crosta, Giorgio; Foccoli, Pierfranco; Pariscenti, Gianluca; Passera, Eliseo; Bortolotti, Luigi; Falezza, Giovanni; Infante, Maurizio; Daffrã¨, Elisa; Cattoni, Maria; Rosso, Lorenzo
Autori di Ateneo:
IMPERATORI ANDREA SELENITO
ROTOLO NICOLA
Link alla scheda completa:
https://irinsubria.uninsubria.it/handle/11383/2064433
Pubblicato in:
JOURNAL OF THORACIC DISEASE
Journal
  • Dati Generali

Dati Generali

URL

http://jtd.amegroups.com/article/download/13560/pdf
  • Accessibilità
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.6.0.0