Development of simulation combining a physical heart model and three-dimensional system for electrophysiology training

Articolo
Data di Pubblicazione:
2018
Abstract:
Background: A new three-dimensional heart anatomical simulator (3D HAS) has been created combining a physical heart model with an electroanatomic mapping (EAM) system. The aim of this study is to describe the development and the validation process of this device. Methods: We developed the 3D HAS combining a physical heart model with an EAM system. This simulator was then validated by 10 electrophysiologists, subdivided in two groups based on their experience in electrophysiology procedures. The performance of the experts was compared to the one of the novices in achieving three different tasks: fluoroless reconstruction of the right atrium, coronary sinus cannulation, and deployment of a linear ablation lesion in the cavotricuspid isthmus. For each operator, a score was calculated based on objective parameter for each task and for the overall performance. Results: The 3D HAS was located in an environment that allowed use of the main features of the EAM system including contact force sensing. No technical issue was encountered during the validation process. The experts’ performance was significantly better than the one of the novices both overall (P = 0.009) and in each task (right atrium reconstruction, P = 0.016; coronary sinus cannulation, P = 0.008; ablation lesion, P = 0.03). Conclusions: The 3D HAS is reliable and allows use of the main features of an EAM system in the right atrium. The ability to discriminate different levels of experience suggests that this simulator is enough realistic and could be useful for electrophysiology training.
Tipologia CRIS:
Articolo su Rivista
Keywords:
ablation; cardiac electrophysiology; simulation training; three-dimensional heart; three-dimensional mapping; Cardiology and Cardiovascular Medicine
Elenco autori:
Rossi, Luca; Penela, Diego; Doni, Lorenzo; Marazzi, Raffaella; Napoli, Velia; Napoli, Leonardo; Vilotta, Manola; Villani, Giovanni Quinto; De Ponti, Roberto
Autori di Ateneo:
DE PONTI ROBERTO
Link alla scheda completa:
https://irinsubria.uninsubria.it/handle/11383/2074968
Pubblicato in:
PACING AND CLINICAL ELECTROPHYSIOLOGY
Journal
  • Dati Generali

Dati Generali

URL

http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159
  • Accessibilità
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.7.0.0