Oxidative potential and chemical composition of PM2.5 in office buildings across Europe - The OFFICAIR study

Articolo
Data di Pubblicazione:
2016
Abstract:
In the frame of the OFFICAIR project, indoor and outdoor PM2.5 samples were collected in office buildings across Europe in two sampling campaigns (summer and winter). The ability of the particles to deplete physiologically relevant antioxidants (ascorbic acid (AA), reduced glutathione (GSH)) in a synthetic respiratory tract lining fluid, i.e., oxidative potential (OP), was assessed. Furthermore, the link between particulate OP and the concentration of the PM constituents was investigated.The mean indoor PM2.5 mass concentration values were substantially lower than the related outdoor values with a mean indoor/outdoor PM2.5 mass concentration ratio of 0.62 and 0.61 for the summer and winter campaigns respectively. The OP of PM2.5 varied markedly across Europe with the highest outdoor OPAA m-3 and OPGSH m-3 (% antioxidant depletion/m3 air) values obtained for Hungary, while PM2.5 collected in Finland exhibited the lowest values. Seasonal variation could be observed for both indoor and outdoor OPAA m-3 and OPGSH m-3 with higher mean values during winter. The indoor/outdoor OPAA m-3 and OPGSH m-3 ratios were less than one with 4 and 17 exceptions out of the 40 cases respectively. These results indicate that indoor air is generally less oxidatively challenging than outdoors. Correlation analysis revealed that trace elements play an important role in determining OP, in particular, the Cu content. Indoor air chemistry might affect OP since weaker correlations were obtained for indoor PM2.5. Our findings also suggest that office workers may be exposed to health relevant PM constituents to a different extent within the same building.
Tipologia CRIS:
Articolo su Rivista
Keywords:
Environmental health; Indoor air quality; Occupational exposure; Office building; Oxidative potential; PM2.5; 2300
Elenco autori:
Szigeti, Tamás; Dunster, Christina; Cattaneo, Andrea; Cavallo, DOMENICO MARIA GUIDO; Spinazzè, Andrea; Saraga, Dikaia E.; Sakellaris, Ioannis A.; de Kluizenaar, Yvonne; Cornelissen, Eric J. M.; Hänninen, Otto; Peltonen, Matti; Calzolai, Giulia; Lucarelli, Franco; Mandin, Corinne; Bartzis, John G.; Záray, Gyula; Kelly, Frank J.
Autori di Ateneo:
CATTANEO ANDREA
CAVALLO DOMENICO MARIA GUIDO
Igiene ambientale e occupazionale (Risk Assessment for Human Health - RAHH)
SPINAZZÈ ANDREA
Link alla scheda completa:
https://irinsubria.uninsubria.it/handle/11383/2050537
Pubblicato in:
ENVIRONMENT INTERNATIONAL
Journal
  • Dati Generali

Dati Generali

URL

www.elsevier.com/locate/envint
  • Accessibilità
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0